MATTECH, s.r.o.
K Myslivně 7/2183
708 00, Ostrava – Poruba
Czech Republic

tel. +420 596 917 277
fax +420 596 916 794
E-mail : info@mattech.cz
Internet : http://www.mattech.cz

:: ORIFICE PLATES ::
:: PATTERN APPROVED METER ::

Print - click here !


Klikni zde pro detail !
Centric orifice plate with individual tapings of pressure differential
 

Orifice plate is a thin stainless-steel plate usually with circular orifice and if its centre is in the axis of piping it is called centric orifice plate. Orifice can also have other shape than circular (see chapter on special orifice plates). Construction simplicity and unambiguous definition by ISO 6167-1 standard, by which they are predetermined for the widest use in all kinds of flow measurements, are their best merits.

Orifice plate is placed in a flange of the piping. In addition to CSN standard the sealing surfaces can be produced in compliance with ISO, DIN, ASME, ANSI or GOST standards as well (or on request of customer). Centric orifice plates are produced either as working meters without verification or as verified ones while meeting assembly conditions stated in pattern approval. In comparison with verified meter tubes, there is one difference: they are not supplied with straightening sections in front of and behind the orifice plate in the piping. Except for the mostly used centric orifice plates other ones with different shapes of plates can be produced as well (see chapter special orifice plates).


Production of plate
 

Centric orifice plates and orifice
plates with individual tapings


ORIFICE PLATES WITH CHAMBER TAPINGS

Chamber orifice plate is produced for the range of nominal inside diameter
DN 15 – DN 1000 for nominal pressures from PN 2.5 – PN 100. Use of chamber orifice plates for higher pressures is not recommended. Main parts of the chamber orifice plates are these: a two-piece flange with annular chamber and a plate. The plate is clamped between two parts of flange and then sealed. The taping outlet of the pressure differential is placed in the flange. The plate can be replaced. Working position of the flow meter can be either vertical or horizontal. Usual construction width of the orifice plate with chamber taping is 60 mm.

flow direction

Diagram of centric orifice plate with chamber tapings

For the production of tapings for chamber orifice plate material 11416, 17248, 17348 is used, for plate 17 248, 17 348. When agreed, the plate or the flange can also be made of a special grade material based on nickel and titanium alloys or tantalum.
 


Plates


Welding of tapings



Table of Dimensions for the Orifice Plates with Chamber Tapings
(usual construction width of the orifice plates with chamber taping is 60 mm)

DN Outer diameter of a flange in compliance with
CSN 13 10 30
weight
of orifice
plate excluded
taping (kg)
PN 6 PN 10 PN 16 PN 25 PN 40 PN 63 PN 100
15 40 47 47 47 47 47 47 0.7
20 50 58 58 58 58 58 58 1.1
25 60 68 68 68 68 68 68 1.5
32 70 78 78 78 78 78 78 2.0
40 80 88 88 88 88 88 88 2.4
50 90 102 102 102 102 102 102 2.9
65 110 122 122 122 122 122 122 4.0
80 128 133 133 133 133 133 133 4.4
100 148 158 158 158 158 158 158 5.5
125 178 184 184 184 184 184 184 6.8
150 202 212 212 212 212 212 212 8.0
200 258 268 268 278 285 285 285 15.8
250 312 320 320 335 345 345 345 21.5
300 365 370 370 390 410 410 410 30.7
350-1000 Inside diameters of piping are determined by discussion with customer

............................................................................................................................

ORIFICE PLATES WITH INDIVIDUAL TAPINGS

Orifice plates with individual tapings are produced for the range of nominal inside diameter from DN 15 to DN 1000 for temperatures and pressures from PN 2.5 to PN 250 (for these pressures nozzles can be used as well). This type of orifice plate has a one-piece flange and a plate is turned out directly in the orifice plate body. Tapings are individual orifices in front of and behind a plate. Orifice plates with individual tapings can be used for measurement in higher operational pressure and temperature. Due to the fact that this orifice plate can not be dismantled, there is lesser probability that any leakage might occur. Its plate can not be replaced. Usual construction width of the orifice plates with individual tapings is 40 mm. Working position of the flow meter can be either horizontal or vertical.

flow direction


Diagram of centric orifice plate with individual tapings

For the production of the individual orifice plates standard materials 15128, 17248, 17348 are used. When agreed, orifice plate with individual tapings can also be made of a special grade material based on nickel and titanium alloys or tantalum.

Dimension Table of the Orifice Plates with Individual Tapings
(usual construction of orifice plates with individual tapings is 40 mm)

DN Outside diameter of the flange
Do in compliance with CSN 13 10 30
  Orifice plate
weight excluded
outlets
(kg)
PN 6 PN 10 PN 16 PN 25 PN 40 PN 63 PN 100 PN 250
15 40 47 47 47 47 47 47 47 0.5
20 50 58 58 58 58 58 58 58 0.7
25 60 68 68 68 68 68 68 68 1.0
32 70 78 78 78 78 78 78 78 1.3
40 80 88 88 88 88 88 88 88 1.5
50 90 102 102 102 102 102 102 102 1.9
65 110 122 122 122 122 122 122 122 2.5
80 128 133 133 133 133 133 133 133 2.8
100 148 158 158 158 158 158 158 158 3.6
125 178 184 184 184 184 184 184 184 4.4
150 202 212 212 212 212 212 212 212 5.2
200 258 268 268 278 285 285 285 285 10.4
250 312 320 320 335 345 345 345 345 14.1
300 365 370 370 390 410 410 410 410 20.3
350 415 430 430 450 465 465 465 - 28.7
400 465 482 482 505 535 535 535 - 35.1
500 570 585 585 615 615 615 615 - 39.8
600 670 685 685 720 735 735 735 - 59.1
700 775 800 800 820 840 840 840 - 68.4
800 880 905 905 930 960 960 - - 80.3
900 980 1005 1005 1030 1070 1070 - - 103.2
1000 1080 1110 1110 1140 1180 1180 - - 133.7