METER TUBES TO VORTEX FLOW METERS AND ANUBARS
Other meters than those constructed on basis of throttling of section
such as vortex flow meters and anubars have to be assembled to
accurately defined meter tube. Its way of assembly, operation and
verification is stated in TMP 6664-01 and TMP 6665-01 issued by ČMI
Brno. Way of assembly of anubars is stated in particular pattern
approval. Our company offers production and supply of these meter
tubes. Meter tube has outlet for welding into piping.

tube with vortex flow meter

tube with vortex flow meter
............................................................................................................................
THERMOMETRIC POCKETS AND WELDED-ON PIECES
 |
Thermometric pockets are designed to prevent
contact of thermometric device with medium flow. When replacing
thermometer, it is not necessary to shut down the device. The
thermometer can be replaced during its operation. Thermometric
welded-on pieces are welded into the piping and it’s purpose is
to clamp the thermometric pocket. |

High-pressure pocket
|

Detailed description (description of high-pressure thermometric
pockets) |
............................................................................................................................
STOP FITTINGS
Together with meters Mattech supplies stop valves of low inside
diameters (DN 10, PN 100-400), various types of union nut and other
machine instrumentation of meter circle.
COUPLING PIECES FOR IMPULSE PIPING
 |
Our company produces and supplies high-pressure
coupling T-pieces for coupling impulse piping of 15 (or 17)
grade material to pressure class PN 250.
|
|
|
|
AIR DISTRIBUTORS
|

Air distributors |

Air distributors |
|