Meter tubes to vortex flow meters and anubars
Other meters than those constructed on basis of throttling of section such as vortex flow meters and anubars have to be assembled to accurately defined meter tube. Its way of assembly, operation and verification is stated in TMP 6664-01 and TMP 6665-01 issued by ČMI Brno. Way of assembly of anubars is stated in particular pattern approval. Our company offers production and supply of these meter tubes. Meter tube has outlet for welding into piping.

tube with vortex flow meter

tube with vortex flow meter
Thermometric pockets and welded-on pieces
Thermometric pockets are designed to prevent contact of thermometric device with medium flow. When replacing thermometer, it is not necessary to shut down the device. The thermometer can be replaced during its operation. Thermometric welded-on pieces are welded into the piping and it's purpose is to clamp the thermometric pocket.
Stop fittings
Together with meters Mattech supplies stop valves of low inside diameters (DN 10, PN 100-400), various types of union nut and other machine instrumentation of meter circle.
Coupling pieces for impulse piping
Our company produces and supplies high-pressure coupling T-pieces for coupling impulse piping of 15 (or 17) grade material to pressure class PN 250.
Air distributors